Armstrong Furnace Products

A96MV High-Efficiency Modulating Furnace

Features

96% AFUE Efficiency Rating

This means 96% of your fuel is converted into usable heat. Compared to an older furnace, this can potentially save you hundreds of dollars per year in energy costs.
Modulating Heat

Provides superior comfort over traditional single- stage and two-stage products, further reducing temperature swings in your home.
Variable Speed Fan Motor

By changing the speed of its airflow during start-up, your furnace can adjust humidity levels and create more even temperatures throughout your home, while enhancing efficiency and reducing operating noise.
Quiet Combustion™ Technology

Uses a smaller Btu input per burner for quieter start-up and operation while providing more even heat distribution.
EHX™ Technology

Every Armstrong Air furnace is engineered and built with EHX Technology, a patented design that eliminates the hot spots that can shorten furnace life. EHX Technology makes heat exchangers more durable, and with its advanced airflow system, more air contacts the heat exchanger surface area for greater heat exchange, enhancing efficiency and comfort.
Advanced Heat Exchanger

Made from stainless steel for maximum strength and crimped, rather than welded, Armstrong Air heat exchangers are highly resistant to thermal fatigue and other stresses caused by repeated heating and cooling. During the testing process, they are subjected to temperatures that far exceed normal operating ranges, to ensure they will stand up to years of use.

Specs

WARRANTY
• 10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.
CONFIGURATIONS
• Upflow / Horizontal • Downflow
HEAT EXCHANGER DESIGN
• 409 stainless steel primary heat exchanger with crimped no-weld construction
• AL 29-4C stainless steel secondary heat exchanger
CABINET DESIGN
• Compact 33” height • Standardized widths for easy coil fit
AIR DELIVERY SYSTEM
• ECMTM variable speed blower motor • Easily removable slide out blower design
CONTROLS
• Modulating gas valve • Self diagnostics saves last 10 fault codes
regardless of power interruption
VENTING
• Category 4 direct vent appliance
INSTALLATION FEATURES
• Left or right utility connections • Zero step horizontal conversion • Removable floor base for bottom return air

A951E Single-Stage, Constant Torque Furnace

Features

95% AFUE Efficiency Rating

This means 95% of your fuel is converted into usable heat. Compared to an older furnace, this can potentially save you hundreds of dollars per year in energy costs.
Constant Torque Motor

Like a variable speed furnace, constant torque furnaces provide lower operating costs and increases to overall system efficiency. Compared to standard PSC motors, constant torque delivers more consistent airflow and quieter operation.
Quiet Combustion™ Technology

Uses a smaller Btu input per burner for quieter start-up and operation while providing more even heat distribution.
EHX™ Technology

Every Armstrong Air furnace is engineered and built with EHX Technology, a patented design that eliminates the hot spots that can shorten furnace life. EHX Technology makes heat exchangers more durable, and with its advanced airflow system, more air contacts the heat exchanger surface area for greater heat exchange, enhancing efficiency and comfort.
Advanced Heat Exchanger

Made from stainless steel for maximum strength and crimped, rather than welded, Armstrong Air heat exchangers are highly resistant to thermal fatigue and other stresses caused by repeated heating and cooling. During the testing process, they are subjected to temperatures that far exceed normal operating ranges, to ensure they will stand up to years of use.

Specs

WARRANTY
• 10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.
CONFIGURATIONS
• Upflow / Horizontal • Downflow
INSTALLATION FEATURES
• Left or right utility connection
• Design certified for direct and non-direct vent applications
• Zero step horizontal conversion
• Removable floor base (upflow / horizontal units) for bottom return air
• Complies with California’s South Coast Air Quality Management district Low NOx requirements
HEAT EXCHANGER DESIGN
• Stainless steel primary heat exchanger with crimped non-welded construction
• AL 29-4C Stainless steel secondary heat exchanger
BURNER
• Aluminized steel inshot burners for smooth ignition
CABINET DESIGN
• Compact 33” height • Standardized widths for easy coil fit
AIR DELIVERY SYSTEM
• Multi-speed high efficiency (constant torque) blower motor
• Easily removable slide out blower design
• Enhanced cooling SEER ratings when applied with properly matched cooling equipment.
CONTROLS
• Single stage gas valve
• Durable silicon nitride ignitor
• Self diagnostics saves last 10 fault codes regardless of power interruption
• Control features electronic air cleaner and humidifier terminals
VENTING
• Designed certified for direct (2-pipe) and non direct (1-pipe) applications
• Easily vented with PVC pipe

A951S High-Efficiency Single-Stage Furnace

Features

95% AFUE Efficiency Rating

This means 95% of your fuel is converted into usable heat. Compared to an older furnace, this can potentially save you hundreds of dollars per year in energy costs.
Quiet Combustion™ Technology

Uses a smaller Btu input per burner for quieter start-up and operation while providing more even heat distribution.
EHX™ Technology

Every Armstrong Air furnace is engineered and built with EHX Technology, a patented design that eliminates the hot spots that can shorten furnace life. EHX Technology makes heat exchangers more durable, and with its advanced airflow system, more air contacts the heat exchanger surface area for greater heat exchange, enhancing efficiency and comfort.
Advanced Heat Exchanger

Made from stainless steel for maximum strength and crimped, rather than welded, Armstrong Air heat exchangers are highly resistant to thermal fatigue and other stresses caused by repeated heating and cooling. During the testing process, they are subjected to temperatures that far exceed normal operating ranges, to ensure they will stand up to years of use.

Specs

WARRANTY
• 10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.
CONFIGURATIONS
• Upflow / Horizontal • Downflow
INSTALLATION FEATURES
• Left or right utility connection
• Design certified for direct and non-direct vent applications
• Zero step horizontal conversion
• Removable floor base (upflow / horizontal units) for bottom return air
• Complies with California’s South Coast Air Quality Management district Low NOx requirements
HEAT EXCHANGER DESIGN
• Stainless steel primary heat exchanger with crimped non-welded construction
• AL 29-4C Stainless steel secondary heat exchanger
BURNER
• Aluminized steel inshot burners for smooth ignition
CABINET DESIGN
• Compact 33” height • Standardized widths for easy coil fit
AIR DELIVERY SYSTEM
• Multi-speed high efficiency (constant torque) blower motor
• Easily removable slide out blower design
• Enhanced cooling SEER ratings when applied with properly matched cooling equipment.
CONTROLS
• Single stage gas valve
• Durable silicon nitride ignitor
• Self diagnostics saves last 10 fault codes regardless of power interruption
• Control features electronic air cleaner and humidifier terminals
VENTING
• Designed certified for direct (2-pipe) and non direct (1-pipe) applications
• Easily vented with PVC pipe